Document / Project Reference
Gas Volume Conversion
Real-gas volume conversion using PV = ZnRT · Manual / Generalized Z / PR / SRK Z-factor basis
Screening-level calculation. Confirm project reference conditions, gas composition and simulator Z-factors for EPC deliverables.
Company—Doc. No.—
Project—Rev.—
Document—Line / Tag—
Calculation Summary
Source
—
Target Result
—
Source Z
—
Target Z
—
Source / Target Basis
ItemSourceTarget
Unit——
Conditions——
Z basis——
Conversion Equation
Equation
—
Warnings / Limitations
—
All Units Summary
UnitValueBasis
—
EoS Composition Summary
SideComponentmol %
Manual / fixed reference Z basis — no composition table used.
Reference Conditions
Nm³/h0 °C, 101.325 kPa(a), Zref = 1.000Sm³/h15 °C, 101.325 kPa(a), Zref = 1.000SCFM / MMSCFD60 °F, 14.696 psia, Zref = 1.000
Source (From) Fixed Reference

Fixed reference: 15 °C, 101.325 kPa(a), Z = 1.000 (ISO 13443)

Target (To) Actual
Target Operating Conditions
Actual-condition unit — supply P, T and Z (manual or computed from EoS).
Z-factor:
User-supplied Z — from simulator, EoS, or validated project data
Result
Converted flow rate
—
Enter source flow rate to calculate.
All Units Summary
Unit Value Basis Note
Enter source flow rate to calculate.
Fixed reference — immutable basis Actual — condition-dependent (shown only when target)
Calculation Trace
Reference Conditions
UnitT refP refZ refStandard
Nm³/h0 °C (273.15 K)101.325 kPa(a)1.000ISO 13443
Sm³/h15 °C (288.15 K)101.325 kPa(a)1.000ISO 13443
SCFM60 °F (288.71 K)14.696 psia (101.325 kPa)1.000GPA 2172
MMSCFD60 °F (288.71 K)14.696 psia (101.325 kPa)1.000GPA 2172
Am³/hUser-supplied operating conditions—
Am³/sUser-supplied operating conditions—
ACFMUser-supplied operating conditions—
Validation: 1 MMSCFD → Sm³/h ≈ 1,177.6 Sm³/h (ISO 13443 / GPA 2172 cross-check)